Connected Light worked directly with the City of London Corporation to review lighting energy use across several of its buildings, surveying the sites and proposing where LED lighting and new controls could reduce consumption.
Vital Energi was appointed to deliver the schemes, and Connected Light supported the work from concept to completion over 10 months. More than 6,000 Casambi nodes were installed, and the upgrade achieved energy savings of over 60%.
At Guildhall, the retrofit covered two areas with different requirements. The North Wing offices needed an upgrade that fitted within the existing service rafts. In the Great Hall, the listed light fittings had to be retained.
The service rafts across all 10 floors had to stay in place. Their angled light apertures housed Cat 2 louvres and T5 fluorescent lamps, and the position and angle of those apertures set the limits for the replacement equipment. The T5 lighting was removed and Connected Light developed the new office lighting design around the existing openings. A new fabricated MPO optical diffuser replaced the Cat 2 louvres, giving UGR19 anti-glare control within the angled aperture.
Connected Light’s fabrication team designed and made the new LED gear trays in-house. Each tray was fully packed with new technology and was made to slot into the space left by the old fluorescent equipment.
The trays incorporated Casambi DALI dimming and integrated wireless emergency lighting using Surepath, so each one went into the raft as a complete unit.
A micro Casambi sensor was used in certain luminaires which activates the office lighting in groups, so it responds in the part of the office being used. The wireless lighting control system is also set up for daylight regulation, reducing LED output when there is enough natural light.
Timed scenes provide a separate lighting arrangement for night-time security.
The Great Hall’s listed fittings could not be replaced, so the heritage lighting design focused on the equipment inside them. Connected Light developed new direct and indirect retrofit gear cartridges to replace the old metal halide and halogen equipment.
The new cartridges were designed to work with the original Lutron controls, so the hall kept both its listed fittings and its existing control system. It is a practical example of modern performance in lighting for historic buildings.
Connected Light provided commissioning throughout the project, including out-of-hours site attendance, installation and programming.
If you are planning an upgrade and need to work with existing fittings or controls, speak to Connected Light about the options available for your site.

The service Connected Light offer to us is invaluable. They have access to a wide range of manufacturers and luminaires that enhance any lighting design, provide the back-up calculations, control philosophy and on-site commissioning.... Read More

I've been a Client of Connected Light when working as a Project Manager for two NHS Trusts in Bristol over the past three years. Every interaction with Matt and the wider team at the company is a positive one... Read More

As a member of BS 5266 I am so excited to see such suitable, diligent, compliant processing from Connected Light. BS 5266 pt. 1 is a Code of practice for the emergency lighting of premises.... Read More

The service Connected Light offer to us is invaluable. They have access to a wide range of manufacturers and luminaires that enhance any lighting design, provide the back-up calculations, control philosophy and on-site commissioning. This makes Connected Light a great resource of knowledge for end to end luminaire and controls capability.
Connected Light have provided support on various projects, especially those with Philips luminaires as they have a very deep knowledge of the range and products on offer, and can integrate with third party lighting controls.

I've been a Client of Connected Light when working as a Project Manager for two NHS Trusts in Bristol over the past three years. Every interaction with Matt and the wider team at the company is a positive one, and everyone I have dealt with has been excellent at explaining legislation, the possibilities with various lighting fixtures and designs. Fee proposals are very reasonable, well presented and complete and Connected Light deliver on what is defined at the outset.
Competence, particularly certified competence, is of paramount importance on the fire safety projects we are working on together, so Connected Light's expertise and accreditations are not only invaluable but also a necessity.
Thank you Connected Light for being a crucial part of our projects and assisting in making our hospital buildings safer, compliant and nicer places to be.

As a member of BS 5266 I am so excited to see such suitable, diligent, compliant processing from Connected Light. BS 5266 pt. 1 is a Code of practice for the emergency lighting of premises. This is the base document that calls up relevant standards and outlines how they should be interfaced. It also details how types of emergency lighting systems should be designed, installed, commissioned, and tested for different types of premises. Installation and wiring considerations are detailed and the appropriate testing and commissioning documentation are defined.
Connected Light as a member of the Fire Industry Association and competent compliance with BAFE SP203 part 4 adheres to appropriate verification for suitable compliance with all of their customers.